• AVVR COPPER CONDUCTOR PVCINSULATED SHEATHED WIRE
  • AVVR COPPER CONDUCTOR PVCINSULATED SHEATHED WIRE

AVVR COPPER CONDUCTOR PVCINSULATED SHEATHED WIRE

Application Scope

Suitable for power connection lines of household appliances, small electric tools, electrical instruments, electronic equipment, lighting of power equipment and other connection lines under an AC rated voltage U0/U of 300/300V and below.
  • AVVR COPPER CONDUCTOR PVCINSULATED SHEATHED WIRE

Description

Usage Characteristics

  • The long-term allowable working temperature shall not exceed 70℃.
  • The laying temperature of the cable shall not be lower than 0℃.
  • Bending radius: If the outer diameter D < 25mm, it should not be < 4D; if the outer diameter D ≥ 25mm, it should not be < 6D.
  • The conductor is copper, and the sheath material is polyvinyl chloride.

DOWNLOAD CATEGORY SPECIFICATIONS


Specification (mm²) Conductor Structure (n/mm) Insulation Thickness (mm) Sheath Thickness (mm) Minimum Outer Diameter (mm) Maximum Outer Diameter (mm) Maximum Conductor Resistance at 20℃ (Ω/km) Minimum Insulation Resistance at 70℃ (MΩ·km) Reference Ampacity (A)
2×0.12 7/0.15 0.4 0.6 3.3 4.3 158.0 0.016 1.4
2×0.2 13/0.15 0.5 0.6 3.6 4.7 92.3 0.014 2.0
2×0.3 19/0.15 0.5 0.6 4.1 5.3 62.2 0.014 3.2
3×0.12 7/0.15 0.4 0.6 3.4 4.5 158 0.016 1.4
3×0.2 13/0.15 0.4 0.6 3.8 4.9 92.3 0.014 2.0
3×0.3 19/0.15 0.5 0.6 4.4 5.7 62.2 0.014 3.2
4×0.12 7/0.15 0.4 0.6 3.9 4.9 158.0 0.016 1.4
4×0.2 13/0.15 0.4 0.6 4.2 5.4 92.3
0.014
2.0
4×0.3
19/0.15
0.5
0.6
4.8
6.2
62.2
0.014
3.2
5×0.12
7/0.15
0.4
0.6
4.1
5.3
158.0
0.016
1.4
5×0.2
13/0.15
0.4
0.6
4.5
5.8
92.3
0.014
2.0
5×0.3
19/0.15
0.5
0.6
5.3
6.7
62.2
0.014
3.2
6-7×0.12
7/0.15
0.4
0.6
4.4
5.7
158.0
0.016
1.4
6-7×0.2
13/0.15
0.4
0.6
4.9
6.3
92.3
0.014
2.0
6-7×0.3
19/0.15
0.5
0.6
5.7
7.3
62.2
0.014
3.2
10×0.12
7/0.15
0.4
0.6
5.7
7.2
158.0
0.016
1.4
10×0.2
13/0.15
0.4
0.6
6.3
8.0
92.3
0.014
2.0
10×0.3
19/0.15
0.5
0.6
7.8
9.7
62.2
0.014
3.2
12×0.12
7/0.15
0.4
0.6
5.8
7.4
158.0
0.016
1.4
12×0.2
13/0.15
0.4
0.6
6.5
8.2
92.3
0.014
2.0
12×0.3
19/0.15
0.5
0.6
8.0
10.1
62.2
0.014
3.2

Note: For parameters of other color modules, please consult local sales and technical personnel.

Other Information

  • Implementation Standard: JB/T 8734.5-2016
  • Rated Voltage: U0/U 300/300V

Download

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Name
Email*
Phone
Message
Leave a message
Name
Email*
Phone
Message